Transition-networks Standalone Media convertor MGE-PSW-SX-01 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 9
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
12
M/GE-PSW-xX-01
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Technical Specifications
For use with Transition Networks Model M/GE-PSW-xX-01 converters.
Standards: IEEE 802.3-2000
Data rate: 10 Mb/s, 100 Mb/s, 1000 Mb/s
Dimensions: 1.8"W x 3.35"D x 0.85"H (45.7 x 85.1 x 21.6 mm)
Weight: 3.15 oz. (127.5 g) approximately
MTBF*: 24,466 hours (MIL217F2 V5.0) (MIL-HDBD-217F)
100,130 hours (Bellcore7 V5.0)
Memory: 1Meg
MAC addresses: 8K
Maximum packet size: 1632 bytes, untagged
1628 bytes, tagged
Power sources: Unit will accept - 5 to 28 VDC
Barrel connector – Wall Mount AC Adapter
(400mA at 12VDC)(The external power supply provided
with this product is UL listed by the power supply’s
manufacturer.)
Power consumption: 262mA @ 12VDC, 3.15 watts
Environment: Tmra**: 0°C to 50°C (32°F to 122°F )
Storage Temp: -25°C to 65°C (-13°F to 149°F)
Humidity: 5% to 95%, non-condensing
Altitude: 0 to 10,000 feet
Warranty: Lifetime
*MTBF is estimated using the predictability method. This method is based on MIL-
217F at 25°C ambient temperature, typical enclosure heat rise of 10°C with nominal
operating conditions and parameters. Installation and configuration specific MTBF
estimates are available upon request. Contact Technical Support.
**Manufacturer’s rated ambient temperature.
CAUTION:
Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232,
RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-
building (inside plant) link segments that are not subject to lightening transients or
power faults. Copper-based media ports, e.g., Twisted Pair (TP) Ethernet, USB,
RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-
building (outside plant) link segments that are subject to lightening transients or power
faults. Failure to observe this caution could result in damage to equipment.
[email protected] -- Click the “Transition Now” link for a live Web chat.
13
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers
to the following questions and then taking the indicated action:
1. Is the power LED illuminated and did the TX and FX LEDs turn ON then turn
OFF?
NO
Is the power adapter the proper type of voltage and cycle frequency for
the AC outlet?
Is the power adapter properly installed in the media converter and in the
outlet?
Contact Technical Support: US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
YES
Proceed to step 2.
Note the following:
As a link pass-through device both copper and fiber cables must be
installed before the LEDs will light.
2. Are the “TX and FX-Link/ACT” LEDs illuminated on the RJ-45 port ?
NO
Check the copper cables for proper connection.
Check the fiber cables for proper connection.
Contact Technical Support: US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
YES
Contact Technical Support: US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
Technical Specifications—Continued
Copper-based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422,
RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-building
(inside plant) link segments that are not subject to lightening transients or power
faults. Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232,
RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-
building (outside plant) link segments that are subject to lightening transients or power
faults.
The product is certified by the manufacturer to comply with DHHS Rule 21/CFR,
Subchapter J applicable at the date of manufacture.
WARNING:
Visible and invisible laser radiation when open. Do not stare into the
beam or view directly with optical instruments. Failure to observe this warning could
result in an eye injury or blindness.
WARNING:
Use of controls, adjustments, or the performance of procedures other
than those specified herein could result in hazardous radiation exposure.
The information in this user’s guide is subject to change. For the most up-to-date
information, view the user’s guide on-line at: www.transition.com.
Page view 6
1 2 3 4 5 6 7 8 9

Comments to this Manuals

No comments